Puno Filter / Guides / Nominal vs absolute rating
Nominal versus absolute filter ratings
A nominal rating removes most particles of the stated size. An absolute rating removes essentially all of them. The same micron number can describe either, which is why two quotes for a 1 micron cartridge can differ so much.
Nominal
A nominal rating means the filter removes a stated share of particles at that size, by weight or by count. The share varies by maker, commonly anywhere from 60 to 98 percent, and the test method is not standardised. Melt-blown and string-wound cartridges are usually nominal.
Absolute
An absolute rating means the filter removes at least 99.9 percent of particles at that size under a defined test. Membrane cartridges are absolute rated.
Beta ratio
The clearest way to state efficiency is the beta ratio: particles of a given size going in, divided by particles of that size coming out.
| Beta ratio | Removed |
|---|---|
| 10 | 90% |
| 100 | 99% |
| 1,000 | 99.9% |
| 5,000 | 99.98% |
What to ask a supplier
- Is the rating nominal or absolute?
- What removal efficiency or beta ratio is it based on?
- Is each cartridge integrity tested, or only sampled?
Which to buy
Use nominal filters where the job is bulk dirt removal and a little carry-over does no harm, such as coarse prefiltration. Use absolute filters wherever something downstream depends on the result: a final filter, a sterilizing step, or protection of a costly membrane. Our polypropylene range includes an absolute-rated type, and the PES and PTFE membrane cartridges are absolute rated.
Request a quote
The more you can tell us about the duty, the closer the first quote will be. A photo or model number of your current cartridge is enough to start.